Utilising a unique patented cable manager, KRONE`s new KM8 Category 6 jack is a radical departure from the famous KRONE IDC style of cable termination.
The cable manager is used to form and hold the wires on the KM8 jack silver plated KRONE LSA-PLUS 45-degree contacts. In addition, the cable manager supports the wires and prevents disturbances after termination. This is all done on the KM8 jack without using the familiar KRONE tool.
This departure from the previous method of terminating results from the recent release of the Category 6 performance level for structured cabling components. Category 6 sets a performance specification for transmission over twisted pair cabling at an upper frequency of 250 MHz, this is two-and-a-half times that of the well known Category 5e standard. Category 6 more than doubles the bandwidth of Category 5e, vastly improves signal-to-noise margins and has much better isolation from external noise, allowing improved transmission performance.
While cables have a very consistent geometry throughout their length, it`s when the signal transitions from a cable to a connector that a potential for discontinuity exists. When frequencies of up to 250 MHz are transmitted there is a quite different set of considerations in cable and connection behaviour. IDC modular jacks have to be user friendly in the field, allowing the installer to easily form and terminate the eight (8) wires. At the same time, the required transmission characteristics at Category 6 performance have to be taken into account. At these frequencies uncontrolled bending of the wires and variation in the distance between wires will have considerable effects on performance.
The KM8`s unique cable manager provides better control over the placement of the wire pairs and automatically resolves the important issue of keeping the unsheathed wire pairs as short as possible up to the 45-degree IDC terminals.
In some circumstances, for example, when terminating and fixing a modular jack on wall outlets, the wires are terminated in the front of the mounting position and the jack is turned.
With the KM8 cable manager we ensure that the performance headroom is actually maintained during installation.
Around and pushed back into the housing with the cable ending up in an uncontrolled and unknown position. This is not such an electrical problem on Category 5e, but without the benefit of a Cable manager at Category 6 frequencies there could be dire consequences for the transmission performance of the circuit. Conventional plastic cable ties must not be used with Category 6 cable.
With undisturbed geometry, KRONE Category 6 cable has impedance of 100 Ohms and a constant NEXT.