Interconnect Systems is in the final stages of the installation and Siemens Telecommunications department is due to move in at the end of this month.
Krone will issue the client with a channel warranty (which includes fully-imported Cat 6 flyleads and patchleads) once the project reaches completion.
Says Tanja Schutte of Krone SA: "The Krone Highband Ultim8 system delivers a future-proof migration strategy for the implementation of new network equipment. The Krone solution also provides high-speed LAN and WAN systems with maximum headroom in transmission performance.
"The standards that specify Cat 6 were finalised in June this year. Cat 6 has a more demanding performance criteria that Cat 5e, and as such, is less forgiving when it comes to the installation methods used.
"For example, sharp bends in the cable route should be avoided, as should kinking or crushing the cables, or the performance of the cabling system will be compromised", she says.
"Other installation issues relating to Cat 6 cabling systems are to keep cable runs to a minimum (this does not apply if cables are installed in cable trays), adhering to correct cable jacket unsheathing recommendations and maintaining the correct cable twist rate, right up to the point of termination".
The computer rooms in each of the new buildings on the Siemens campus are linked by means of a fibre-optic backbone. Interconnect Systems has installed one 800 pair floor standing Krone frame in each of the three computer rooms. These frames are positioned alongside the equipment cabinets.
The cabling project manager of Interconnect Systems, Nico van der Westhuizen, developed a cost-effective method of routing cable bundles from the cable trays in the ceiling on to the patching frames.
He installed lengths of 100mm x 100mm industrial trunking on to the back of each Krone frame, and then drilled holes into the face of each length of trunking at regular intervals.
Cable bundles feed downward through the trunking, then out of these holes, where they are cable-tied on to the patching frame.
A special colour-coding and labelling system simplifies the administration of the Krone Highband cabling system.
Strain relief
Interconnect Systems custom-designed special transition boxes for this installation, which feature built-in strain relief.
The transition boxes are fitted on to the cable trays, which have been installed in the ceiling void. When the installation reaches completion, flyleads will drop down from the transition boxes, through power poles, to the workstation clusters that will populate the open-plan office spaces.
Because of this special strain-relief facility, it will be difficult for users to pull flyleads out of the network points, as these are actually cable-tied on to the boxes.
Clipsal power skirting has been installed in each of the buildings and flush-mount Krone Cat 6 network outlet points have been installed directly into the power skirting covers.
With this type of power skirting system, Interconnect has been able to print relatively large network point identification labels, which have been positioned so that they face upwards.
The maintenance technicians will save time because they will not need to crouch down in order to see the numbering when searching for a specific network point. The numbering is large enough to read from a standing position.
Louis Braun from Interconnect comments:
"The combined experience of Siemens and ourselves, coupled with the fact that there was good communication between us from the start, has led to the success of this installation".